1、Operating system: Widnows 9x/Me/NT/2K/XP

2、Dual-channel to work independently,External;
3、Output Voltage Range:-500mv~1500mv
4、Sensitivity of 1 microvolt points / sec, a minimum resolution 0.1uV, the smallest peak width 0.1s。
5、Input impedance:>10MΩ
6、Dynamic range :107, Linearity:±0.01%;
7、Repeatability:±0.01%
8、The maximum sampling frequency 100次/秒
9、Noise:±1μV(High-precision 24-bit digital-to-analog conversion)
10、USBCommunications,At the same time a number of channel data acquisition;
11Equipped with a remote start switch, can also be keyboard or mouse shortcut menu. Injection can be automatically connected to the trigger switch, automatic start or shut down analysis of sample data; with a variety of supporting Autosampler used for automatic data processing.
液相检测应用
高效液相色谱HPLC检测方案
-样品处理过程-
精密称取供试品约25mg,置50ml容量瓶中,加流动相溶解并定量稀释至刻度,摇匀,经针式过滤器过 滤,即得
-色谱条件-
色谱柱:Vertex C18:250mm×4.6mm×5μm
流动相:流动相A:流动相B=2.5:97.5
配制方法:流动相A:乙腈
流动相B:0.05mol/L磷酸二氢钾溶液(用2mol/L氢氧化钾溶液调节PH值为5.0)
波长:254nm
流速:1. 0 mL/min
进样量:20ul
仪器配置:请点击查看图片详情
![]() | 501Plus型高压恒流提供了溶剂及压缩因子库,可自动进行溶剂补偿。。。。。。 | ![]() | 501Plus型紫外检测器采用的氘灯,光源稳定,基线噪音、飘移极低,另外还有钨灯可选,氘灯质保寿命1000Hrs。。。。。。 | ![]() | 7725i进样阀是目前的HPLC样品进样阀。采取定量环全充满及部分充满方式,可以处理1μl至5ml的样品量。 |