通信电缆 网络设备 无线通信 云计算|大数据 显示设备 存储设备 网络辅助设备 信号传输处理 多媒体设备 广播系统 智慧城市管理系统 其它智慧基建产品
深圳市旭鸿通信技术有限公司
25G SFP28 SR 多模模块 工作温度范围 商业级:0℃ to 70℃ 工业级:-40℃ to 85℃ 获取报价
产品特性
◆ 双纤LC接口
◆ 热插拔SFP28封装
◆ 内置数字诊断功能
◆ 内置CDR芯片
◆ 在多模光纤中传输距离达到100米
◆ +3.3V单电源供电
◆ 符合RoHS6标准
◆ 工作温度范围 商业级:0℃ to 70℃ 工业级:-40℃ to 85℃
◆ 低功耗<1.0W
产品应用
◆ 数据中心
◆ 25G以太网
◆ 32G光纤通道
◆ 服务器、交换机、存储主机光纤网卡
光学参数/Optical transmitter Characteristics | ||||||
Parameter | Symbol | Min | Typical | Max | Unit | Notes |
Launched Power (avg.) | POUT | -8.4 | 2.4 | dBm | ||
Optical Power OMA | POMA | -6.4 | 3 | dBm | ||
Operating Wavelength Range | λC | 840 | 850 | 860 | nm | |
Spectral Width (RMS) | ∆λ | 0.6 | nm | |||
Extinction Ratio | ER | 2 | dB | |||
Transmitter and Dispersion Penalty | TDP | 4.3 | dB | |||
Optical Output Power after TX Disable | PDIS | -30 | dBm | |||
Relative Intensity Noise | RIN | -128 | dB/Hz | |||
Optical Return Loss Tolerance | ORL | 12 | dB | |||
Optical Receiver Characteristics | ||||||
Parameter | Symbol | Min | Typical | Max | Unit | Notes |
Wavelength Range | λC | 840 | 850 | 860 | nm | |
Average Receiver Power | Pmax | -10.3 | 2.4 | dBm | ||
Receiver Sensitivity (Average power) | Psen |
-10.3 | dBm | 1,2 | ||
LOS De-Assert | LOSD | -13 | dBm | |||
LOS Assert | LOSA | -30 | dBm | |||
LOS Hysteresis | 0.5 | dB | ||||
Receiver Reflectance | Rr | -12 | dB |
Notes:
1.Measured with a PRBS 231-1 test pattern, @25.78125Gb/s, BER<5E-5.
2.Minimum value is informative, equals min Tx OMA with infinite ER and max channel insertion loss.
引脚定义
The SFP28 modules are hot-pluggable. Hot pluggable refers to plugging in or unplugging a module while the host board is powered. The SFP28 host connector is a 0.8 mm pitch 20 position right angle improved connector specified by SFF-8431, or stacked connector with equivalent electrical performance. SFP28 module contacts mates with the host in the order of ground, power, followed by signal as illustrated by Figure 1 and the contact sequence order listed in Table 1.
Figure 1 SFP28 Pad Assignment Top View
Pin No | Symbol | Name/Description | Power Seq. | Note |
1 | VeeT | Transmitter Ground | 1st | 1 |
2 | TX_Fault | Transmitter Fault | 3rd | 2 |
3 | TX_Disable | Transmitter Disable | 3rd | 3 |
4 | SDA | 2-Wire Serial Interface Data Line | 3rd | 4 |
5 | SCL | 2-Wire Serial Interface Data Line | 3rd | 4 |
6 | Mod_ABS | Module Absent, Connect to VeeT or VeeR in Module | 3rd | 5 |
7 | RS0 | No connection required | 3rd | 6 |
8 | RX_LOS | Receiver Loss of Signal indication | 3rd | 7 |
9 | RS1 | No connection required | 3rd | 8 |
10 | VeeR | Receiver Ground | 1st | 1 |
11 | VeeR | Receiver Ground | 1st | 1 |
12 | RD- | Receiver Inverted DATA out. AC Coupled. CML-O | 3rd | 9 |
13 | RD+ | Receiver Non-inverted DATA out. AC Coupled. CML-O | 3rd | 9 |
14 | VeeR | Receiver Ground | 1st | 1 |
15 | VccR | Receiver Power Supply | 2nd | 10 |
16 | VccT | Transmitter Power Supply | 2nd | 10 |
17 | VeeT | Transmitter Ground | 1st | 1 |
18 | TD+ | Transmitter Non-Inverted DATA in. AC Coupled. CML-I | 3rd | 11 |
19 | TD- | Transmitter Inverted DATA in. AC Coupled. CML-I | 3rd | 11 |
20 | VeeT | Transmitter Ground | 1st | 1 |
Power Seq.: Pin engagement sequence during hot plugging.
Notes:
1.The module signal ground contacts.
2.This pin is an open drain/collector and should be pulled up to Vcc-host in the host with a 4.7k~10k Ohm resistor.
3.This pin should be pulled up to VccT with a 4.7k~10k Ohm resistor in modules.
4.SDA&SCL (IIC) are needed pull up 4.7k~10k Ohm resistors on host board.
5.Mod_ABS is connected to VeeT or VeeR in the SFP28 module.
6.Rate Select 0, no connection required.
7.Module RX_Los of signal indication need pull up 4.7k~10k Ohm resistor on host board.
8.Rate Select 1, no connection required.
9.RD -/+: These are the differential receiver outputs. They are CML AC-coupled with 100 Ohm terminal resistor matching internal.
10.VccR and VccT are the receiver and transmitter power supplies.
11.TD-/+: These are the differential transmitter inputs. They are CML AC-coupled with 100 Ohm terminal resistor matching internal
订购信息
型号/PART NO. | 产品描述Specifications | |||||||
Pack | Rate | Tx | Po | Sen | Temp | Reach | DDM | |
(Gbps) | (nm) | (dBm) | (dBm) | (℃) | (m) | |||
HD-SFP28/25G-SR |
SFP28 |
25.78125 |
850 |
-8.4~2.4 |
<-10.3 |
0~70 |
100 |
Y |
*Note:
1.Measured with a PRBS 231-1 test pattern, @25.78125Gb/s, BER<5E-5.
2.OM3 Cable length =<70m or OM4 Cable length =<100m.
3.More detail product selection and cable lengths, please contact xuhong
您感兴趣的产品PRODUCTS YOU ARE INTERESTED IN
智慧城市网 设计制作,未经允许翻录必究 .
请输入账号
请输入密码
请输验证码
请输入你感兴趣的产品
请简单描述您的需求
请选择省份