配备多种机能的小型模拟定时器。从短时间到长时间的时间控制。
|
UL/C-UL , CE Approved
The operation mode and time range can be switched by using the MODE and RANGE switches on the front panel.
1.The lineup consists of 64 easy-to-choosemodels.
2.An operation mode fixed type (S1DXM-A) and 4-operation mode switching type (S1DXM-M) are available.
To eliminate environmentally harmful chemical substances, relays with cadmium-free contacts are used.
1.Prices set to lower costs.
2.Further cost reduction when used with HJ Relay terminal socket.
UL and C-UL approved.
Operation mode | |
---|---|
Power ON-delay operation | When power is turned on, the output contact operates after the set time. The output contact remains on until the power is turned off. |
Operation mode | |
---|---|
Power ON-delay operation [MODE] switch 1: OFF, switch 2: OFF | . When power is turned on, the output contact operates after the set time. The output contact remains on until the power is turned off. |
Power Flicker OFF start operation [MODE] switch 1: OFF, switch 2: ON | When the power is turned on, the output contacts repeatedly operate at the set time. The output contact begins from the off state. |
Power Flicker ON start operation [MODE] switch 1: ON, switch 2: OFF | When power is turned on, the output contact operates repeatedly at the set time. The output contact outputs at the same time power turns on. |
Power One-shot operation [MODE] switch 1: ON, switch 2: ON | When power is turned on, the output contact performs the on operation at the same time power turns on, only for the set time. |
Type | Time scale | Time unit | Min.scale | Max.scale | Setting range | ||||||
---|---|---|---|---|---|---|---|---|---|---|---|
S1DXM-A | 10M type | ×1 | ×10 | s | m | 0.05 | 1 | 0.05 to 1s | 0.5 to 10s | 0.05 to 1m | 0.5 to 10m |
30M type | s | m | 0.2 | 3 | 0.2 to 3s | 2 to 30s | 0.2 to 3m | 2 to 30m | |||
60M type | s | m | 0.5 | 6 | 0.5 to 6s | 5 to 60s | 0.5 to 6m | 5 to 60m | |||
10H type | m | h | 0.05 | 1 | 0.05 to 1m | 0.5 to 10m | 0.05 to 1h | 0.5 to 10h | |||
S1DXM-M | 10M type | ×1 | ×10 | s | m | 0.05 | 1 | 0.05 to 1s | 0.5 to 10s | 0.05 to 1m | 0.5 to 10m |
30M type | s | m | 0.2 | 3 | 0.2 to 3s | 2 to 30s | 0.2 to 3m | 2 to 30m | |||
60M type | s | m | 0.5 | 6 | 0.5 to 6s | 5 to 60s | 0.5 to 6m | 5 to 60m | |||
10H type | m | h | 0.05 | 1 | 0.05 to 1m | 0.5 to 10m | 0.05 to 1h | 0.5 to 10h |
* | The time setting range is the combination of the time scale (X1 or X10) on the dial and the time unit (s, m, or h). Example: When dial reads 1,time scale is X1 and time units is seconds, then it is 1 second. |
---|
Operation mode | Power ON-delay | Power Flicker OFF start | Power Flicker ON start | Power One-shot |
---|---|---|---|---|
Operation mode switch |
Time range switch | |||
---|---|---|---|
The time setting can be switched among 4 ranges each for 4 types for an interval between 0.05 seconds and 10 hours. |
1* | The product is factory shipped with all settings on the OFF side (left). |
---|---|
2* | Do not operate the switches with a sharp-edged object such as a knife blade. |
3* | The power must be turned off when setting the time range or operation mode. Operating the switches with the power on is a cause of breakdown and malfunction. |
4* | Use a force of under 5 N to operate the DIP switches when setting the time range and operation mode. |
Return to top
Operating voltage | Time range | Timed-out 2 Form C | Timed-out 4 Form C |
---|---|---|---|
Part Number | Part Number | ||
12V DC | 0.05s to 10 min | S1DXM-A2C10M-DC12V | S1DXM-A4C10M-DC12V |
0.2 s to 30 min | S1DXM-A2C30M-DC12V | S1DXM-A4C30M-DC12V | |
0.5 s to 60 min | S1DXM-A2C60M-DC12V | S1DXM-A4C60M-DC12V | |
0.05 min to 10 hr | S1DXM-A2C10H-DC12V | S1DXM-A4C10H-DC12V | |
24V DC | 0.05 s to 10 min | S1DXM-A2C10M-DC24V | S1DXM-A4C10M-DC24V |
0.2 s to 30 min | S1DXM-A2C30M-DC24V | S1DXM-A4C30M-DC24V | |
0.5 s to 60 min | S1DXM-A2C60M-DC24V | S1DXM-A4C60M-DC24V | |
0.05 min to 10 hr | S1DXM-A2C10H-DC24V | S1DXM-A4C10H-DC24V | |
100 to 120V AC | 0.05 s to 10 min | S1DXM-A2C10M-AC120V | S1DXM-A4C10M-AC120V |
0.2 s to 30 min | S1DXM-A2C30M-AC120V | S1DXM-A4C30M-AC120V | |
0.5 s to 60 min | S1DXM-A2C60M-AC120V | S1DXM-A4C60M-AC120V | |
0.05 min to 10 hr | S1DXM-A2C10H-AC120V | S1DXM-A4C10H-AC120V | |
200 to 220V AC | 0.05 s to 10 min | S1DXM-A2C10M-AC220V | S1DXM-A4C10M-AC220V |
0.2 s to 30 min | S1DXM-A2C30M-AC220V | S1DXM-A4C30M-AC220V | |
0.5 s to 60 min | S1DXM-A2C60M-AC220V | S1DXM-A4C60M-AC220V | |
0.05 min to 10 hr | S1DXM-A2C10H-AC220V | S1DXM-A4C10H-AC220V |
Operating voltage | Time range | Timed-out 2 Form C | Timed-out 4 Form C |
---|---|---|---|
Part Number | Part Number | ||
12V DC | 0.05 s to 10 min | S1DXM-M2C10M-DC12V | S1DXM-M4C10M-DC12V |
0.2 s to 30 min | S1DXM-M2C30M-DC12V | S1DXM-M4C30M-DC12V | |
0.5 s to 60 min | S1DXM-M2C60M-DC12V | S1DXM-M4C60M-DC12V | |
0.05 min to 10 hr | S1DXM-M2C10H-DC12V | S1DXM-M4C10H-DC12V | |
24V DC | 0.05 s to 10 min | S1DXM-M2C10M-DC24V | S1DXM-M4C10M-DC24V |
0.2 s to 30 min | S1DXM-M2C30M-DC24V | S1DXM-M4C30M-DC24V | |
0.5 s to 60 min | S1DXM-M2C60M-DC24V | S1DXM-M4C60M-DC24V | |
0.05 min to 10 hr | S1DXM-M2C10H-DC24V | S1DXM-M4C10H-DC24V | |
100 to 120V AC | 0.05 s to 10 min | S1DXM-M2C10M-AC120V | S1DXM-M4C10M-AC120V |
0.2 s to 30 min | S1DXM-M2C30M-AC120V | S1DXM-M4C30M-AC120V | |
0.5 s to 60 min | S1DXM-M2C60M-AC120V | S1DXM-M4C60M-AC120V | |
0.05 min to 10 hr | S1DXM-M2C10H-AC120V | S1DXM-M4C10H-AC120V | |
200 to 220V AC | 0.05 s to 10 min | S1DXM-M2C10M-AC220V | S1DXM-M4C10M-AC220V |
0.2 s to 30 min | S1DXM-M2C30M-AC220V | S1DXM-M4C30M-AC220V | |
0.5 s to 60 min | S1DXM-M2C60M-AC220V | S1DXM-M4C60M-AC220V | |
0.05 min to 10 hr | S1DXM-M2C10H-AC220V | S1DXM-M4C10H-AC220V |
Return to top
|
|
|
|
|
|
|
Return to top
ADX18012 | AD68002 | ||
---|---|---|---|
Figure | Dimensions | Figure | Dimensions |
ADX28005 |
---|
Dimensions |
Type | Application | |||
---|---|---|---|---|
Terminal socket | ADX18012 | AD68002 | ADX28005 | |
For HC relay | AP3821 | - | ||
AP3827K | - | |||
AP3847K | - | |||
For HJ relay | AHJ3821 | - | - | |
AHJ38211 | - | - | ||
AHJ3848 | - | - | ||
AHJ38481 | - | - |
The triangles indicate that removal will be slightly difficult when installed laterally in succession. |
Return to top
|
|
|
|
|
|
Name / Part No. | Terminal socket, HC 2-pin HC2-SF-K | |
---|---|---|
Dimensions | Note) Only wire springs can be used.(Plate springs cannot be used.) | |
Terminal layout | ||
Mounting hole dimensions | Panel hole dimensions for side-by-side mounting | |
Applicable timers | S1DX(2c), S1DXM(2c) | S1DX(4c), S1DXM(4c) |
Available | Not Available |
Name / Part No. | Terminal socket, HC 2-pin HC4-HSF-K | |
---|---|---|
Dimensions | Note) Only wire springs can be used.(Plate springs cannot be used.) | |
Terminal layout | ||
Mounting hole dimensions | Panel hole dimensions for side-by-side mounting | |
Applicable timers | S1DX(2c), S1DXM(2c) | S1DX(4c), S1DXM(4c) |
Available | Available |
Name / Part No. | Slim DIN terminal socket,HC2 HC2-SFD-S | |
---|---|---|
Dimensions | ||
Terminal layout | ||
Mounting hole dimensions | ||
Applicable timers | S1DX(2c), S1DXM(2c) | S1DX(4c), S1DXM(4c) |
Available | Not Available |
Name / Part No. | HJ2h terminal socket HJ2-SFD | |
---|---|---|
Dimensions | ||
Terminal layout | ||
Mounting hole dimensions | ||
Applicable timers | S1DX(2c),S1DXM(2c) | S1DX(4c), S1DXM(4c) |
Available | Not Available |
Name / Part No. | HJ2h terminal socket(Finger protect type) HJ2-SFD-S | |
---|---|---|
Dimensions | ||
Terminal layout | ||
Mounting hole dimensions | ||
Applicable timers | S1DX(2c),S1DXM(2c) | S1DX(4c), S1DXM(4c) |
Available | Not Available |
Name / Part No. | HJ4 terminal socket HJ4-SFD | |
---|---|---|
Dimensions | ||
Terminal layout | ||
Mounting hole dimensions | ||
Applicable timers | S1DX(2c),S1DXM(2c) | S1DX(4c), S1DXM(4c) |
Available | Available |
Name / Part No. | HJ4 terminal socket(Finger protect type) HJ4-SFD-S | |
---|---|---|
Dimensions | ||
Terminal layout | ||
Mounting hole dimensions | Drilling size of panel holes for installing the terminal sockets parallel | |
Applicable timers | S1DX(2c),S1DXM(2c) | S1DX(4c), S1DXM(4c) |
Available | Available |
Name / Part No. | Socket HC 2-pin HC2-SS-K | |
---|---|---|
Dimensions | The difference between the HC2 and HC4 sockets is only the number of the pins. Their appearances and sizes are the same. General tolerance: ±0.5 ±.020 | |
Mounting hole dimensions | The thickness of applicable chassis plates ranges from 1.0 to 2.0 mm .039 to .079 inch. To install the socket easily, insert the socket top surface into the drilled holes and press the two points on the fastening plate indicated by arrows as shown in the fig. below. Dimensional tolerance of machining: ±0.1 ±.004 | |
Applicable timers | S1DX(2c),S1DXM(2c) | S1DX(4c), S1DXM(4c) |
Available | Not Available |
Name / Part No. | Socket, HC 4-pin HC4-SS-K | |
---|---|---|
Dimensions | The difference between the HC2 and HC4 sockets is only the number of the pins. Their appearances and sizes are the same. General tolerance: ±0.5 ±.020 | |
Mounting hole dimensions | The thickness of applicable chassis plates ranges from 1.0 to 2.0 mm .039 to .079 inch. To install the socket easily, insert the socket top surface into the drilled holes and press the two points on the fastening plate indicated by arrows as shown in the fig. below. Dimensional tolerance of machining: ±0.1 ±.004 | |
Applicable timers | S1DX(2c),S1DXM(2c) | S1DX(4c), S1DXM(4c) |
Available | Available |
*Sockets for PC board HC2-Socket for PC board: AP3825K HC4-Socket for PC board: AP3845K |
Return to top
Return to top
General tolerance : ±0.5 ±0.20
|
|
|
General tolerance : ±0.5 ±0.20
|
|
|
Return to top
您感兴趣的产品PRODUCTS YOU ARE INTERESTED IN
智慧城市网 设计制作,未经允许翻录必究 .
请输入账号
请输入密码
请输验证码
请输入你感兴趣的产品
请简单描述您的需求
请选择省份