通信电缆 网络设备 无线通信 云计算|大数据 显示设备 存储设备 网络辅助设备 信号传输处理 多媒体设备 广播系统 智慧城市管理系统 其它智慧基建产品
深圳市连讯达电子技术开发有限公司
梅凯Megger DET4T2系列DET4TD2|DET4TR2|DET4TC2|DET4TCR2绝缘电阻测试仪
梅凯Megger MIT300|MIT310|MIT310A|MIT320| MIT330绝缘电阻测试仪
梅凯Megger MIT400/2|MIT410/2|MIT420/2 |MIT430/2 四类绝缘测试仪
梅凯Megger MIT481/2 和 MIT485/2绝缘电阻测试仪
梅凯Megger MIT2500高压手持式绝缘和连续性测试仪
梅凯Megger DLRO100E,DLRO100X及DLRO100H高度便携微欧表100A
梅凯Megger MIT415/2 和 MIT417/2绝缘电阻测试仪
梅凯Megger MIT200|MIT210|MIT220|MIT230绝缘电阻测试仪
梅凯Megger MOM600A,MOM200A微欧计(回路电阻计)
梅凯Megger DET2/3高分辨率接地测试仪DET2/3RC
梅凯Megger DLRO10HDX低电阻微欧计DLRO10HD
梅凯Megger DET14C 和 DET24C接地电阻测试仪
梅凯Megger S1-1568直流绝缘电阻测试仪 15 kV
梅凯Megger S1-1068直流绝缘电阻测试仪S11068
EXFO光功率计PX1,PX1-PRO,PX1-S-PRO,PX1-H-PRO,PX1-S-PRO,PX1-H-PRO
EXFO FPM-600光功率计FPM-602 FPM-602X
EXFO FTBx-720C LAN/WAN接入网OTDR光时域反射仪
EXFO FTBx-730C PON FTTx/MDU OTDR光时域测试仪
EXFO FTBx-735C城域网/PON FTTx/MDU OTDR
EXFO MaxTester 720C - 接入网OTDR光时域反射仪
EXFO MaxTester 730C PON/城域网OTDR光时域反射仪
EXFO ELS-50光源ELS-50-23BL单模ELS-50-12C多模光源
EXFO FPM-300光功率计FPM-302,FPM-302X
EXFO FLS-300单多模光源FLS-300-12D,FLS-300-235BL
NetAlly TEST-ACC吞吐测试选件(iPerf服务器)TEST-ACC-5PK/TEST-ACC-10PK
NetAlly Aircheck G2无线网络测试仪AIRCHECKG2-TA-KT
NetAlly LinkRunner 10G网络测试仪LR10G-100|LR10G-100-KIT|EXG-LR10G-KIT
NetAlly LRAT-2000/LRAT-1000网络测试仪LinkRunner AT(LRAT-2000-KIT)
NetAlly LinkRunner G2智能网络测试仪LR-G2,LR-G2-KIT,LR-G2-ACKG2-CBO
NetAlly AirMagnet Wi-Fi Analyzer PRO无线分析仪(AM/A1150)
NetAlly EXG-200|EXG-200-KIT网络测试仪EtherScope nXG
NetAlly LSPRNTR-300网络测试仪LinkSprinter
NetAlly AirMagnet Survey PRO无线勘测仪WLAN分析工具(AM/A4018)
NetAlly AirMagnet Spectrum XT频谱分析仪(AM/B4070|AM/A4040)
NetAlly 1TG2-3000/1TG2-1500网络性能测试仪1T10G-1000
NetAlly EXG-200-KIT|EXG-200-KIT-2PK|EXG-200-LRG2-KIT|EXG-LR10G-KIT网络测试仪EtherScope nXG
NetAlly AirCheck G3 Pro 第三代无线网络测试分析仪
NETSCOUT 1TG2-3000-2PAK|1TG2-1500-2PAK|1T10G-1000-2PAK|网络测试助手Onetouch AT G2
NETSCOUT LRAT-1000|LRAT-2000网络测试仪LinkRunner AT
NETSCOUT AirMagnet Survey无线测试仪
NETSCOUT AirMagnet Spectrum XT无线频谱分析仪
NETSCOUT LSPRNTR-300 网络测试仪LinkSprinter
NETSCOUT AirMagnet WiFi Analyzer PRO无线网络测试仪
NetAlly(NetScout) 1TG2-1500-LRAT2/1TG2-3000-LRAT2网络测试仪
NETSCOUT 1TG2-1500|1TG2-3000|1T10G-1000网络测试仪
NETSCOUT LR-G2|LR-G2-KIT智能网络测试仪LinkRunner G2|LR-G2-LS-KIT报价 图片 参数
暂无信息 |
阅读:11发布时间:2024-12-27
Since the original IEEE 802.3af Type 1 power over Ethernet (PoE) standard that delivered up to 15.4 Watts (W) was first introduced in 2003, the technology has evolved to include Type 2 (up to 30 W), Type 3 (up to 60 W), and Type 4 (up to 90 W). That means PoE voltage now supports everything from phones, Wi-Fi access points, and surveillance cameras, to laptops, digital displays, and even facility-wide LED lighting—all requiring various levels of PoE power.
To help manage PoE requirements, IEEE also assigns classes to PoE systems that range from 0 to 8. Type 1 and Type 2 PoE encompass Class 0 through Class 4 (4–40 W), Type 3 includes Class 5 (45 W) and Class 6 (60 W), and Type 4 includes Class 7 (75 W) and Class 8 (90 W). That essentially means you could have 8 different classes of PoE devices supported by a single PoE switch or other power sourcing equipment (PSE). And when one of those devices isn’t getting power, you need the ability to troubleshoot it.
PoE Not Working?
There are a variety of reasons why a PoE device might not be working. Lack of continuity due to poor terminations such as opens, shorts, and miswirings, as well of cable damage along a link, can obviously prevent any signal—data or PoE—from transmitting. Increased insertion loss due to heat rise or poor DC resistance unbalance performance can also be a culprit, as well as a device that is not compliant with IEEE PoE standards. When a link has passed certification testing, you have verified continuity, and a standards-compliant PoE device is still not receiving power, the problem could be the active power sourcing equipment (PSE).
On a PoE-enabled switch, the amount of PoE power is allocated per port based on the requirements of its connected device. Allocation allows the switch to supply power with greater efficiency. For example, a typical 24-port PoE-enabled switch may have a power budget of 740 W for powered devices, enabling up to 30 W (Type 2) on each port. With such a wide variety of PoE devices now residing on the network, it’s pretty much guaranteed that not every connected device will require the full 30 W from the switch—you could have a VoIP phone requiring just 7 W of PoE power from one switch port and surveillance camera requiring 15.4 W on another switch port.
Through allocation, the amount of PoE power delivered on a specific port can be reduced. By the same token, PoE power can be increased on a port to support a device that requires more power. The basic rule of thumb is: for a connected device to receive an adequate level of power to operate, the PoE power delivered via the PSE must be equal to or greater than the class of its connected device. For that to happen for all devices connected to the PSE, the total power required for all the devices cannot exceed the total power budget of the PSE.
While today’s advanced PoE switches can determine power requirements of connected devices via power-negotiation messages and allocate power appropriately, problems can arise when that communication malfunctions, PoE has been manually (and incorrectly) allocated per port, the overall power budget of the switch has been oversubscribed, or the equipment can’t support the device requirements. And that calls for more advanced troubleshooting.
How to Check PoE on a Switch Port
Network switches use standards-based link layer discovery protocol (LLDP) or Cisco discovery protocol (CDP) that allow them to discover connected devices and advertise their capabilities. These protocols can be used to acquire information about a switch and a specific port, including port ID, VLAN, advertised speeds, and PoE. Fluke Networks LinkIQ Cable + Network Tester has the ability to receive discovery protocol packets from a switch for a given link and place a load on the connection to ensure that the advertised power is actually what is being delivered across the cabling to the device. This is referred to as PoE load testing.
As a PoE load tester, LinkIQ shows which pairs of a four-pair network cable are carrying power, the negotiated power class (0-8) and the loaded power in watts provided by the PSE at the device. It also shows the minimum required volts that the device needs to meet under load based on the negotiated power class and the actual measured volts under load to ensure it meets that requirement. Because power negotiation between the PSE and PD occurs both at the hardware and software levels to ensure that a device has the capability to connect to the network and to allow for dynamic allocation by the PoE switch, LinkIQ shows this information for both the hardware and software class. A PoE device fails testing with LinkIQ if its negotiated hardware or software class is greater than the power the PSE can deliver. It also fails if the PSE cannot deliver power to the device because the maximum power which the switch can deliver is already in use—in other words, the power has been oversubscribed.
LinkIQ shows you how to check if a switch is PoE enabled and even indicates if the switch can negotiate single signature power or dual signature power. A single-signature device maintains the same power signature across both pair sets (pairs 1,2 and 3,6 and pairs 4,5 and 7,8) while a dual-signature device can have independent power signatures on each pair set, either 1,2 and 3,6 (Dual A) or 4,5 and 7,8 (Dual B). This information is useful because IEEE 802.3bt (Type 3 and Type 4) supports both topologies, and if your switch only supports single-signature devices, it may need to be updated to support dual-signature 802.3 bt devices.
While certification testing will tell you if an installed cabling plant will support PoE and simple wiremap testers will identify continuity issues, once active devices are installed, Fluke Networks LinkIQ with its switch negotiation and PoE load testing capabilities is ideal for more advanced PoE testing.
智慧城市网 设计制作,未经允许翻录必究 .
请输入账号
请输入密码
请输验证码
请输入你感兴趣的产品
请简单描述您的需求
请选择省份