通信电缆 网络设备 无线通信 云计算|大数据 显示设备 存储设备 网络辅助设备 信号传输处理 多媒体设备 广播系统 智慧城市管理系统 其它智慧基建产品
上海沪震实业有限公司
暂无信息 |
阅读:419发布时间:2015-4-30
补体3a(C3a)检测试剂盒说明书
适用生物 Homo sapiens (Human,人)
检测范围 0.156-10ng/mL 灵敏度 0.061ng/mL
样本类型 Serum, plasma and other biological fluids
实验时长 4.5h 实验方法 双抗夹心法 规格 96T
补体3a(C3a)检测试剂盒说明书
ELISA Kit for Complement Component 3a (C3a)
FOR IN VITRO AND RESEARCH USE ONLY, NOT FOR USE IN CLINICAL DIAGNOSTIC PROCEDURES!
补体3a(C3a)检测试剂盒说明书Organism species Homo sapiens (Human)
Product No. SEA387Hu
Sample type Serum, plasma and other biological fluids
Format 96-well strip plate
Assay length 4.5 hours
Detection range 0.156-10ng/mL The standard curve concentrations used for the ELISA’s were 10ng/mL, 5ng/mL, 2.5ng/mL, 1.25ng/mL, 0.625ng/mL, 0.313ng/mL, 0.156ng/mL
Sensitivity The minimum detectable dose of this kit is typically less than 0.061ng/mL.
补体3a(C3a)检测试剂盒说明书Specificity
This assay has high sensitivity and excellent specificity for detection of Complement Component 3a (C3a).
No significant cross-reactivity or interference between Complement Component 3a (C3a) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Complement Component 3a (C3a) and the recovery rates were calculated by comparing the measured value to the expected amount of Complement Component 3a (C3a) in samples.
补体3a(C3a)检测试剂盒说明书
Matrix Recovery range (%) Average(%)
serum(n=5) 89-103 92
EDTA plasma(n=5) 99-105 102
heparin plasma(n=5) 97-105 101
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Complement Component 3a (C3a) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Complement Component 3a (C3a) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Complement Component 3a (C3a) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample 1:2 1:4 1:8 1:16
serum(n=5) 89-101% 79-97% 90-101% 80-102%
EDTA plasma(n=5) 95-102% 90-98% 85-99% 80-101%
heparin plasma(n=5) 85-104% 91-98% 94-104% 84-102%
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents Quantity Reagents Quantity
Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4
Standard 2 Standard Diluent 1×20mL
Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B 1×120μL Assay Diluent B 1×12mL
TMB Substrate 1×9mL Stop Solution 1×6mL
Wash Buffer (30 × concentrate) 1×20mL Instruction manual 1
Assay procedure summary
1. Prepare all reagents, samples and standards;
2. Add 100μL standard or sample to each well. Incubate 2 hours at 37oC;
3. Aspirate and add 100μL prepared Detection Reagent A. Incubate 1 hour at 37oC;
4. Aspirate and wash 3 times;
5. Add 100μL prepared Detection Reagent B. Incubate 30 minutes at 37oC;
6. Aspirate and wash 5 times;
7. Add 90μL Substrate Solution. Incubate 15-25 minutes at 37oC;
8. Add 50μL Stop Solution. Read at 450nm immediay.
Test principle
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Complement Component 3a (C3a). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Complement Component 3a (C3a). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Complement Component 3a (C3a), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Complement Component 3a (C3a) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
智慧城市网 设计制作,未经允许翻录必究 .
请输入账号
请输入密码
请输验证码
请输入你感兴趣的产品
请简单描述您的需求
请选择省份