EMOD EC71/62-175 3.3KW/2000RPM;Mot-Nr.3795029 电机3
REAR MANOMETER
Code: M
VISUAL INDICATOR
Code: V
Scale -14.5 ÷ 0 psi (-1 ÷ 0 bar) Pressure setting -2.2 psi (-0,15 bar)
ELECTRICAL INDICATOR
Code: E
1
3 2
Pressure setting -2.2 psi (-0,15 bar)
Max. working voltage
220 VCA
30 VCC
Max. working current 0,5 A (resistivity)
0,2 A (inductive)
Protection class IP65
Contacts N.O. and N.C.
HF 620 / HF 625
ICAT008-003 002 21
01/03.2011
INDICATORS FOR RETURN LINE
DIFFERENTIAL VISUAL INDICATOR
Code: D (only for 20 and 30 series)
Pressure setting 21.8 psi (1,5 bar)
DIFFERENTIAL VISUAL INDICATOR
Code: H (only for 40 and 50 series)
Pressure setting 21.8 psi (1,5 bar)
DIFFENTIAL ELECTRICAL-VISUAL INDICATOR
Code: L (only for 40 and 50 series)
Pressure setting 21.8 psi (1,5 bar)
Max. working voltage
220 VCA
30 VCC
Max. working current 0,5 A (resistivity)
EMOD EC71/62-175 3.3KW/2000RPM;Mot-Nr.3795029 电机3Protection class IP65
Contacts N.O. and N.C.
2 3 1 N.C. N.O.
HF 620 / HF 625
22 002 ICAT008-003
01/03.2011
IN / OUT PORTS
GAS THREAD BSPP
Cylindrical GAS thread (55°) in accordance with UNI - ISO 228
CODE
Nominal
size A B C
mm (in) mm (in) Nm (lbf in)
GE 3/4" G 3/4 24,5
(0.9645)
20
(0.7873)
30 +2,5
(266 ÷ 288)
GG 1" 1/4 G 1 1/4 39
(1.5354)
24
(0.9448)
60 +5
(531 ÷ 575)
GH 1" 1/2 G 1 1/2 45
(1.7716)
26
(1.0236)
70 +5
(620 ÷ 664)
Filter type
PORTS TYPE
Nominal
size
Gas NPT SAE
BSPP ODT
HF 620-20
HF 625-20
3/4" GE NE OD
HF 620-30
HF 625-30
1" 1/4 GG NG OG
HF 620-40
HF 620-50
1" 1/2 GH NH OH
HF 620 / HF 625
ICAT008-003 002 23
01/03.2011
IN / OUT PORTS
NPT THREAD NPT
NPT thread (60°) in accordance with ANSI - ASME B1-20
CODE
Nominal
size A B C
mm (in) mm (in) Nm (lbf in)
NE 3/4" 3/4 NPT 23,5
(0.9251)
14
(0.5511)
25 +1
(221 ÷ 230)
NG 1" 1/4 1 1/4 NPT 38,5
(1.5157)
18
(0.7086)
50 +2,5
(442 ÷ 464)
NH 1" 1/2 1 1/2 NPT 44
(1.7322)
18,5
(0.7283)
70 +5
(620 ÷ 664)
SAE J514 THREAD ODT
American thread UNC-UNF 60° in accordance with ANSI B 1.1
CODE
Nominal
size A B C
mm (in) mm (in) Nm (lbf in)
OD 3/4" 1 1/16" - 12 UNF - 2B 24,7
(0.9724)
20
(0.7873)
40 +2,5
(354 ÷ 376)
OG 1" 1/4 1 5/8" - 12 UNF - 2B 39,1
(1.5393)
20
(0.7873)
70 +5
(620 ÷ 664)
OH 1" 1/2 1 7/8" - 12 UNF - 2B 45,3
(1.7834)
20
(0.7873)
100 +5
(885 ÷ 929)
HF 620 / HF 625
24 002 ICAT008-004
ASSEMBLY AND REPLACING ELEMENT INSTRUCTIONS
01/03.2011
MOUNTING
Once you have checked the integrity of the filter inside its
package, proceed as follow:
A Take off the protection cap from the in/out ports.
B Secure the filter in the head through the holes of the upper
side (pos.2) tightening them as follows:
HF 620-20/30 and HF 625-20/30 = 44 lbf in (5 Nm)
HF 620-40 and HF 620-50 = 62 lbf in (7 Nm)
C Connect circuit's pipes to inlet and outlet ports using the
tightening torque indicated on pages 22 and 23.
D If the filter has a clogging indicator (pos.3 - 4 - 5 - 6 - 7 - 8), take
the protection cap off and screw the indicator in the dedicated
seat, then tighten to a tightening torque of 266 lbf in (30 Nm). If
the indicator is electric, complete the required connections.
E Start the circuit for a few minutes.
F Make sure there are no leaks.
REPLACING ELEMENT
Once the working hour limit indicated in the manteinance
instructions of the system is reached or when the clogging
indicators point out the limit pressure drop created inside the
filter, the element must be replaced. Pay attention to the
drainage of hydraulic oil, therefore prepare suitable containers to
collect it.
Proceed as follows:
A Stop the system in "machine stopped" status.
B Secure any shut-off valves on the hydraulic circuit.
C Remove the clogged element by hands-crewing it from the