扬州市拓腾电气有限公司
免费会员

当前位置:扬州市拓腾电气有限公司>>电热电器系列>>电伴热带>> BHR81A-15Z/2二通接线盒

BHR81A-15Z/2二通接线盒

参  考  价面议
具体成交价以合同协议为准

产品型号

品       牌

厂商性质生产商

所  在  地扬州市

更新时间:2016-08-18 16:48:22浏览次数:656次

联系我时,请告知来自 智慧城市网
同类优质产品更多>
BHR81A-15Z/2二通接线盒,扬州市拓腾电气增安型防爆接线盒符合GB83836.3-2000的防爆规定,在II类1区和2区防爆场所供并联带安装用。 Incremental safety explosion proof junction box complies with the requirements specified in G83836.
BHR81A-15Z/2二通接线盒
Explosion Proof Junction Box
1.BHR81A-15Z/2二通接线盒产品简介
 Brief Introduction of Product 
   
  • 增安型防爆接线盒符合GB83836.3-2000的防爆规定,在II类1区和2区防爆场所供并联带安装用。

    Incremental safety explosion proof junction box complies with the requirements specified in G83836.3-2000.This is applied in Zone 2, Grade II, for parallel connection cable purpose.

  • 隔爆型防爆接线盒符合GB83836.2-2000的防爆规定,在II类1区和2区防爆场所供串联带安装用。

    Flameproof enclosure junction box complies with the requirements specified in G83836.3-2000. This is applied in Zone 1,2, Grade II, for series connection cable purpose.

 
2.产品技术参数
Product Technical Parameters
名称
name
电源接线盒
Power Junction Box
二通接线盒
Two-way Junction Box
三通接线盒
Three-way Junction Box
终端接
线盒
Terminal Junction Box
热电阻
接线盒
Thermal resistance Junction Box
隔爆型接线盒
Flameproof Enclisure Junction Box
项目
ltem
型号
Type
BHR81A-
15D/3

BHR81A-
15Z/2

BHR81A-
15Z/3
BHR81A-
15F/1
BHR81-
15R/3
BHR85-
60
额定电压
Rated Voltage
220V/380V220V-660V
额定电流
Rated Current
15A60A
绝缘电阻
Insulation Resistance
 ≥50MΩ ≥50MΩ
防护等级
Ingress protection
1P56IP56
外形尺寸
Size
178*60*57135*60*35135*77*3545*20*51178*60*57230*190*120
防爆标志
Explosion Proof Label
ExeIIBT4
用途

Application

电源电缆与并
联带的连接
 

Connection between powercable and parallel connection cable

两根并联带
之间的连接
 

Connection between two parallel connection cables

三根并联带
之间的连接
 

Connection between three parallel connection cables

并联带的
尾端密封
 

End sealing of parallel connection cables

热电阻与控
制电缆连接
 

Connection between thermalresist-
ance and con-
trol cable

串联带与电缆
/串联带连接
和尾端密封

connection between series cables and power cables, series cables/connec-tion and End Sealing

3.并联带用防爆接线盒安装示意图
Installing Sketch of Explosion proof Junction Box for Paralles connection cable  
4.产品安装注意事项
Points to Be Noticed for Product Installation  
 (1)发现接线盒外壳有变形、裂痕和损坏、应停止使用。
 Where there is distortion,crack or damage on the junction box,it must be stopped using.
 (2)安装时应防止电热丝和外编织铜丝及芯线之间的短路。
 When installing,avoid any short circuits between electric heating wires, braided copper wires and core wires.
 (3)应按电热带的型号选用所附适当的密封圈。
 Choose proper sealing rings according to the types of electric heating cables

 

实物拍摄